CẢI TIẾN BỘ LỌC CHO NGHỊCH LƯU MỘT PHA NỐI LƯỚI TRONG HỆ THỐNG ĐIỆN MẶT TRỜI ÁP MÁI
Thông tin bài báo
Ngày nhận bài: 22/03/22                Ngày hoàn thiện: 25/04/22                Ngày đăng: 27/04/22Tóm tắt
Từ khóa
Toàn văn:
PDF (English)Tài liệu tham khảo
[1] M. Q. Duong, N. T. N. Tran, G. N. Sava, and M. Scripcariu, “The Impacts of Distributed Generation Penetration into the Power System,” 2017 International Conference on Electromechanical and Power Systems (SIELMEN), 2017, pp. 295-301.
[2] M. Q. Duong, N. Thien, N. A. M. Tran, G. N. Sava, and V. Tanasiev, “Design, performance and economic efficiency analysis of the photovoltaic rooftop system,” Rev. Roum. Scie. – Techn. Électrotechn. et Énerg., vol. 64, no. 3, pp. 229-234, 2019.
[3] A. Routray, K. D. Mistry, S. R. Arya, and B. Chittibabu, "Power output evaluation of a wind–solar farm considering the influence parameters," IET Renewable Power Generation, vol. 15, no. 8, pp. 1613-1623, 2021.
[4] H. Cha and T. K. Vu, “Study and Design of L-C-L Filter for Single-Phase Grid-Connected PV Inverter”, The Korean Institute of Electrical Engineers' Conference, 2009, pp. 228-230.
[5] L. Wang, R. Yan, and T. K. Saha, "Voltage regulation challenges with unbalanced PV integration in low voltage distribution systems and the corresponding solution," Applied Energy, vol. 256, p. 113927, 2019.
[6] Q. Nguyen, H. V. Padullaparti, K.-W. Lao, S. Santoso, X. Ke, and N. Samaan, "Exact optimal power dispatch in unbalanced distribution systems with high PV penetration," IEEE Transactions on Power Systems, vol. 34, no. 1, pp. 718-728, 2018.
[7] M. Q. Duong, V. T. Nguyen, A. T. Tran, G. N. Sava, and T. M. C. Le, “Performance assessment of low-pass filters for standalone solar power system,” in 2018 International Conference and Exposition on Electrical and Power Engineering (EPE) (Iasi), 2018b, pp. 503-507, doi: 10.1109/ICEPE.2018.8559942
[8] Mathworks, “Single-phase PWM Inverter”, 2021 [Online]. Available: https://ch.mathworks.com/help/physmod/sps/ug/single-phase-pwm-inverter.html. [Accessed Oct. 20, 2021].
[9] N. F. Roslan, J. A. Suul, A. Luna, I. Candela, and P. Rodriguez, "A simulation study of proportional resonant controller based on the implementation of frequency-adaptive virtual flux estimation with the LCL filter," IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society, 2015, pp. 001934-001941, doi: 10.1109/IECON.2015.7392383.
[10] W. Wu, Y. He, T. Tang, and F. Blaabjerg, “A New Design Method for the Passive Damped LCL and LLCL Filter-Based Single-Phase Grid-Tied Inverter,” IEEE transactions on industrial electronics, vol. 60, no. 10, pp. 4339-4350, October 2013.
[11] IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems, IEEE Standard 519, 2014.
[12] M. Huang, X. Wang, P. C. Loh, and F. Blaabjerg, "Design of LLCL-filter for grid-connected converter to improve stability and robustness," 2015 IEEE Applied Power Electronics Conference and Exposition (APEC), 2015, pp. 2959-2966, doi: 10.1109/APEC.2015.7104772.
[13] W. Wu, Y. He, and F. Blaabjerg, “An LLCL Power Filter for Single-Phase Grid-Tied Inverter”, IEEE transactions on power electronics, vol. 27, no. 2, pp. 782-789, February 2012.
[14] Amendment 1 - Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase), IEC Standard 61000-3-2, 2018.DOI: https://doi.org/10.34238/tnu-jst.5738
Các bài báo tham chiếu
- Hiện tại không có bài báo tham chiếu